Identifier: knb-lter-sbc.1006.8 (in the knb Catalog System)

Data Table

REQUEST DATA:
Available Online:
 Download data after acceptance of SBC LTER Data Use Agreement:
Name: LTER06_CTD_upcasts.txt
Description: Profiles of binned upcasts from SeaBird 911-plus CTD system averaged over 1m bins. File format is acceptable input for Ocean Data View.
Additional Info:
Number of Columns: 50
Geographic Region:
Description: geocov_ctdupcast.ds1006.e2: Data table bounding box coordinates
Bounding Coordinates:
Northern:   34.4625 Southern:   34.0258
Western:   -120.5595 Eastern:   -119.2805
Altitude Minimum: -579.997 Altitude Maximum: 0
Time Period:
Begin:
2003-02-28
End:
2003-03-05
Table Structure:
Object Name: LTER06_CTD_upcasts.txt
Size: 3997964 byte
Text Format:
Number of Header Lines: 1
Record Delimiter: \n
Orientation: column
Simple Delimited:
Field Delimiter: ;
Collapse Delimiters: no
Quote Character: "
Table Column Descriptions
  Cruise Station Name cast type date time Longitude Latitude Bot. Depth [m] Depth SW [m] Decimal Year [yr] longitude latitude pressure water temperature, from primary sensor water temperature, from secondary sensor water conductivity, from primary sensor water conductivity, from secondary sensor scansPerBin Fluorescence Irradiance, Photosynthetically Available Radiation fraction of surface PAR Surface Irradiance Photosynthetically Available Radiation v0 v1 v2 v3 v4 v5 v6 v7 light transmission Beam attenuation coefficient Dissolved Oxygen Dissolved Oxygen Dissolved Oxygen Dissolved Oxygen Temperature from Beckman/YSI O2 sensor potential temperature from first sensor pair potential temperature from second sensor pair Salinity from first sensor pair Salinity from second sensor pair sigma-theta, potential density anomaly from first sensor pair sigmatheta, potential density anomaly from second sensor pair specific volume anomaly from first sensor pair specific volume anomaly from second sensor pair nitrate isus mbari xderv1 xderv2 xderv3 xderv4
Column Name Cruise  
Station  
Type  
mon/day/yr  
hh:mm  
Lon (degE)  
Lat (degN)  
Bot. Depth [m]  
Depth SW [m]  
Decimal Year [yr]  
lon  
lat  
Pressure [db]  
T00  
T11  
C00  
C11  
scans/bin  
Fluor  
par  
cpar  
spar  
v0  
v1  
v2  
v3  
v4  
v5  
v6  
v7  
Trans [%]  
Beam C  
DIssolved Oxygen [umol/kg]  
DIssolved Oxygen [ml/l]  
O2 Beckman YSI [umol/kg]  
O2 Beckman YSI [ml/l]  
O2 Beckman YSI Temperature [C]  
potemp00  
potemp11  
sal00 [PSU]  
sal11 [SPU]  
sigma00  
sigma11  
sva00  
sva11  
nitrate_isus  
xderv1  
xderv2  
xderv3  
xderv4  
Definition name of Cruise, column required by ODV composed of a string describing the activity and cast number plus the station name, column required by ODV cast type at this station, column required by ODV format is mm/dd/yyyy, column required by ODV time, UTC, in 24 hr format, column required by ODV Longitude for first sample at the station, east is positive. Column required by ODV: requires all samples which are to be considered at same station to have the same latitude in this column. Latitude for first sample at the station, north is positive. Column required by ODV: requires all samples which are to be considered at same station to have the same latitude in this column. depth to the bottom at this station, column required by ODV based on seawater density, average depth for points in this bin. Positive is down, column required by ODV year (yyyy) plus day-time as a fraction of a year, ie, half way thru 2005 = 2005.5 longitude of this measurement, recorded by the CTD, east is positive latitude of this measurement, recorded by the CTD, north is positive center of the pressure averaging interval ITS-90, based on International Temperature Scale of 1990 TS-90, based on International Temperature Scale of 1990 Conductivity, from primary sensor Conductivity, from secondary sensor the number of data lines averaged in this bin Estimated chl contentration from in-situ fluorometer Irradiance from a 4-pi (spherical) sensor ratio of PAR at depth to surface PAR (as percent) ________ Irradiance at the surface PAR ________ voltage, 0 channel, raw data for diagnostic purposes voltage, 1 channel, raw data for diagnostic purposes voltage, 2 channel, raw data for diagnostic purposes voltage, 3 channel, raw data for diagnostic purposes voltage, 4 channel, raw data for diagnostic purposes voltage, 5 channel, raw data for diagnostic purposes voltage, 6 channel, raw data for diagnostic purposes voltage, 7 channel, raw data for diagnostic purposes percent of light emitted by a source reaching a sensor across a path of known length (usually 0.25m) calculated from transmission accordiing to: Beam attenuation coefficient c = - ( 1 / (path length[m]) * ln ( light transmission [decimal] ) oxygen concentration from the SeaBird Electronics sensor oxygen concentration from the SeaBird Electronics sensor oxygen concentration from the Beckman - Yellow Springs Instruments sensor oxygen contentration from the Beckman - Yellow Springs Instruments sensor output by the Beckman - Yellow Springs Instruments sensor Temperature after the effects of compression have been removed. Defined as the temperature of a parcel of water at the sea surface after it has been raised adiabatically from some depth in the ocean Temperature after the effects of compression have been removed. Defined as the temperature of a parcel of water at the sea surface after it has been raised adiabatically from some depth in the ocean Salinity calculated according to the "Practical Salinity Scale of 1978" Salinity calculated according to the "Practical Salinity Scale of 1978" Density anomaly calculated with in situ salinity, potential temperature and pressure=0. sigmatheta = density[kg/m3] - 1000kg/m3. (International Equation of State, Joint Panel on Oceanographic Tables and Standards, 1981) Density anomaly calculated with in situ salinity, potential temperature and pressure=0. sigmatheta = density[kg/m3] - 1000kg/m3. (International Equation of State, Joint Panel on Oceanographic Tables and Standards, 1981) difference between the in situ specific volume (m3/kg) of a parcel and specific volume at the same pressure with S=35 and T=0[celsius]. difference between the in situ specific volume (m3/kg) of a parcel and specific volume at the same pressure with S=35 and T=0[celsius] measured with Satlantic ISUS (In-Situ Ultraviolet Spectrophotometer). Accuracy = 2uM or 10% currently empty, reserved for a future derived parameter currently empty, reserved for a future derived parameter currently empty, reserved for a future derived parameter currently empty, reserved for a future derived parameter
Storage Type string  
string  
string  
string  
string  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
float  
string  
string  
string  
string  
Measurement Type nominal nominal nominal dateTime dateTime ratio ratio ratio ratio ratio ratio ratio ratio interval interval ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio ratio interval interval interval interval interval interval interval interval interval ratio nominal nominal nominal nominal
Measurement Values Domain
Definition any text
Allowed values and definitions
Allowed values and definitions
Format mm/dd/yyyy
Precision 1
Format hh:mm
Precision 1
Unit degree
Precision 1e-05
Type real
Min -180 
Max 180 
Unit degree
Precision 1e-05
Type real
Min -90 
Max 90 
Unit meter
Precision 1
Type real
Unit meter
Precision 0.001
Type real
Min
Max 1000 
Unit nominalYear
Precision 1e-09
Type real
Unit degree
Precision 1e-05
Type real
Min -180 
Max 180 
Unit degree
Precision 1e-05
Type real
Min -90 
Max 90 
Unit decibar
Precision 0.001
Type real
Min
Max 1000 
Unit celsius
Precision 0.0001
Type real
Min
Max 100 
Unit celsius
Precision 0.0001
Type real
Min
Max 100 
Unit siemensPerMeter
Precision 0.0001
Type real
Unit siemensPerMeter
Precision 0.0001
Type real
Unit number
Precision 1
Type integer
Unit volt
Precision 0.001
Type real
Unit microeinsteinPerMeterSquaredPerSecond
Precision 0.1
Type real
Unit percent
Precision 0.001
Type real
Min
Max 100 
Unit microeinsteinPerMeterSquaredPerSecond
Precision 0.001
Type real
Unit volt
Precision 0.001
Type real
Min
Max
Unit volt
Precision 0.001
Type real
Min
Max
Unit volt
Precision 0.001
Type real
Min
Max
Unit volt
Precision 0.001
Type real
Min
Max
Unit volt
Precision 0.001
Type real
Min
Max
Unit volt
Precision 0.001
Type real
Min
Max
Unit volt
Precision 0.001
Type real
Min
Max
Unit volt
Precision 0.001
Type real
Min
Max
Unit percent
Precision 0.001
Type real
Min
Max 100 
Unit reciprocalMeter
Precision 0.001
Type real
Unit micromolePerKilogram
Precision 0.001
Type real
Unit milliliterPerLiter
Precision 0.001
Type real
Unit micromolePerKilogram
Precision 0.001
Type real
Unit milliliterPerLiter
Precision 0.001
Type real
Unit celsius
Precision 0.001
Type real
Unit celsius
Precision 0.0001
Type real
Unit celsius
Precision 0.0001
Type real
Unit dimensionless
Precision 0.0001
Type real
Unit dimensionless
Precision 0.0001
Type real
Unit kilogramPerMeterCubed
Precision 0.0001
Type real
Unit kilogramPerMeterCubed
Precision 0.0001
Type real
Unit cubicMeterPerKilogram
Precision 0.0001
Type real
Unit cubicMeterPerKilogram
Precision 0.0001
Type real
Unit micromolePerLiter
Precision 0.001
Type real
Definition any text
Definition any text
Definition any text
Definition any text
Missing Value Code
Code 99999
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999.00000
Expl no measurement collected at this point, or not available
Code 99999.00000
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000000000
Expl no measurement collected at this point, or not available
Code 99999.00000
Expl no measurement collected at this point, or not available
Code 99999.00000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.0
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.0000
Expl no measurement collected at this point, or not available
Code 99999.000
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Code 99999
Expl no measurement collected at this point, or not available
Accuracy Report                                                                                                    
Accuracy Assessment                                                                                                    
Coverage   Coverage Info                                                                                                
Methods